Home > Buy Now > Electronic Measuring Instruments > Oscilloscopes > 20/40MHz Oscilloscope Expand Vertical Sensitive To 10~20V/D
 


Shenzhen Matrix Technology Inc.
 
icon Function Generator
icon DDS Function Generator
icon Oscilloscope
icon Power Supply
icon Toroidal Transformer
icon Frequency Counter
icon LCR meter
icon Genset Controller

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Shenzhen Matrix Technology Inc.
[China]
Address:
Building.B, No.5 East Wing, Shangxue Technology City, Bantian, Longgang, Shenzhen, China Shenzhen Guangdong 518129 China
Phone:
86-755-61217025
Contact name:
Neo Mo
Inquire now










Shenzhen Matrix Technology Inc.



 
Oscilloscope

20/40MHz Oscilloscope Expand Vertical Sensitive To 10~20V/D

Inquire now

20/40MHz Oscilloscope Expand Vertical Sensitive To 10~20V/D

Click to enlarge image

 Model Number MOS-620B/640B

 
Specification
 

 

  • VERTICAL AXIS
  • Sensitivity: 5mV~20V/DIV,12 steps in 1-2-5 sequence (X5 MAG: 1mV/DIV)
  • Sensitivity accuracy: ≤ 3% ( × 5 MAG: ≤ 5% )
  • Vernier vertical sensitivity: Continuously variable to 1/2.5 or less of panel-indicated value
  • Frequency
  • Bandwidth: DC~20MHz ( × 5MAG:DC~7MHz) / DC~40MHz (X5MAG: DC~15MHz)
  • AC coupling: Low limit frequency 10Hz.
  • (With reference to 100KHz, 8DIV. Frequency response with-3dB.)
  • Rise time:Approx.17.5nS( × 5MAG:Approx.50nS) / Approx. 9.5nS (X5MAG: Approx. 25nS)
  • Input impedance:Approx.1M Ω /Approx.25pF
  • Square wave characteristics: Overshoot: ≤ 5%(At 10mV/DIV range);
  • Other distortions and other ranges:5% added to the above value
  • DC balance shift: 5mV~5V/DIV; ±0.5DIV, 1mV~2mV/DIV±2.0DIV
  • Linearity: ≤± 0.1DIV of amplitude change when waveform of 2DIV at graticule center is moved vertically
  • Vertical modes: CH1: CH2 single channel;
  • DUAL: CH1 and CH2 are displayed simultaneously.
  • ALT or CHOP selectable at any sweep rate;
  • ADD: CH1+CH2 algebraic addition
  • Chopping repetition frequency: Approx.250KHz
  • Input coupling: AC, GND , DC
  • Maximum input voltage: 300Vpeak (AC: frequency 1KHz or lower);When set probe switch at 1:1, the maximum effective readout is 40Vp p(14Vrms at sine wave); or set probe switch at 10:1, the maximum effective readout is 400Vpp(140Vrms at sine wave).
  • Common mode rejection ratio: 50:1 or better at 50KHz sinusoidal wave. (When sensitivities of CH1 and CH2 are aet equally)
  • Isolation between channels(At 5mV/DIV range): > 1000:1 at 50KHz; > 30:1 at 20MHz/ > 30:1 at 40MHz
  • CH1 signal output: At least 20mV/DIV into a 50 Ω termination. Bandwidth is 50Hz to at least 5MHz
  • CH2 INV BAL: Balanced point variation: ≤ 2DIV(Reference at center graticule)
  • TRIGGERING
  • Triggering source: CH1, CH2, LINE, EXT
  • Coupling: AC:20Hz to full bandwidth
  • Slope: +/-
  • Sensitivity: 20Hz~2MHz:0.5DIV, TRIG-ALT:2DIV, EXT:200mV; 2~2MHz:1.5DIV; 20MHz~40MHz: 2DIV, TRIG-ALT:3DIV, EXT:800mV; TV: Sync pulse more than 1DIV (EXT:1V)
  • Triggering modes: AUTO; NORM ; TV-V ; TV-H; (Both TV-V and TV-H synchronize only when the synchronizing signal is negative)
  • EXT triggering signal input:
  • Input impedance: Approx:1M Ω /approx.25pF
  • Max. input voltage: 300V(DC+AC peak), AC: Frequency not higher than 1KHz
  • HORIZIONTAL AXIS
  • Sweep time: 0.2 μ Sec~0.5Sec/DIV, 20steps in 1-2-5 sequence;
  • Sweep time accuracy: ± 3%;
  • Vernier sweep time control: ≤ 1/2.5 of panel-indicated value;
  • Sweep magnification: 10 times;
  • × 10MAG sweep time accuracy: ±5 %(20nSec~50nSec are uncalibrated);
  • Linearity: ± 3%, × 10MAG: ±5 %(20nSec~50nSec are uncalibrated);
  • Position shift caused by × 10MAG: Within 2DIV. at CRT screen center
  • X-Y MODE:
  • Sensitivity: Same as vertical axis. (X-axis: CH1 input signal;Y-axis:CH2 input signal.);
  • Frequency bandwidth: DC to at least 500KHz;
  • X-Y phase difference: ≤ 3°at DC-50KHz
  • Z AXIS
  • Sensitivity: 5Vp-p (Positive-going signal decreases intensity);
  • Frequency bandwidth: DC~2MHz;
  • Input resistance: Approx.47K Ω ;
  • Maximum input voltage:3V(DC+AC peak, AC frequency ≤ 1KHz)
  • CALIBRATION VOLTAGE
  • Waveform: Positive-going square wave;
  • Frequency: Approx.1KHz; Duty ratio: Within 48:52;
  • Output voltage: 2Vp-p ± 2%;
  • CRT
  • Type: 6-inch rectangular type, internal graticule;
  • Phosphor:P31;
  • Acceleration voltage: Approx.2KV(20MHz) / Approxl12KV (40MHz);
  • Effective screen size: 8 × 10DIV (1DIV=10mm(0.39in);
  • Trace rotation: Provided

 

NOTE :
  • 20MHz/40MHz Dual Channel
  • High Sensitivity 1mV/DIV
  • Z Axis Input
  • CH1 Output
  • 10 times sweep magnification
  • TV Synchronization, X-Y mode
  • High luminance, internal graticule
  • Encoder for Sweep and Vert mode switch
  • ALT Triggering Function, simultaneous observation of two independant signalls
  • Triggering Level Lock Function
  • Buit in 1000:1 attenuator expanded vertical sensitivity to 10V~20V/DIV




Inquire now